For many decades, the lead-acid battery has been the most widely used energy-storage device for medium- and large-scale applications (approximately 100Wh and above). In recent years, the traditional, flooded design of the battery has begun to be replaced by an alternative design. This version - the valve-regulated lead-acid (VRLA) battery - requires no replenishment of the water content of the electrolyte solution, does not spill liquids, and can be used in any desired orientation. Since the VRLA battery operates in a somewhat different manner from its flooded counterpart, considerable technological development has been necessary to meet the exacting performance requirements of the full range of applications in which rechargeable batteries are used.
The valve-regulated design is now well established in the industrial battery sector, and also appears set to be adopted widely for automotive duty.
This book provides a comprehensive account of VRLA technology and its uses. In the future, all industrial processes - including the manufacture of batteries - will be required to conform to the conventions of sustainability. Accordingly, the crucial areas of the environmental impact associated with the production and use of VRLA batteries and the recycling of spent units are also treated thoroughly.
Valve-Regulated Lead-Acid Batteries gives an essential insight into the science that underlies the development and operation of VRLA batteries and is a comprehensive reference source for those involved in the practical use of the technology in key energy-storage applications.
- Covers all major advances in the field
- Provides a comprehensive account of VRLA technology and its uses
- First book dedicated to this technology
Inhaltsverzeichnis
1;Cover;1 2;Preface;6 3;List of Contributors;8 4;Contents;10 5;Abbreviations, Symbols and Units Used Repeatedly in Text;20 6;1 The Valve-regulated Battery;28 6.1;Lead--Acid Batteries --- A Key Technology for Energy Sustainability;28 6.2;The Lead--Acid Battery;29 6.3;The Valve-regulated Battery;34 6.4;Heat Management in Lead--Acid Batteries;37 6.4.1;Heat generation;37 6.4.2;Heat dissipation;38 6.5;The Challenges Ahead;39 6.6;References;41 7;2 Lead Alloys for Valve-regulated Lead--acid Batteries;42 7.1;Antimony-free Grid Alloys;42 7.2;Pure-lead Positive Grids;42 7.3;Lead--Calcium Alloys;43 7.4;Tin Additions to Pure Lead and Lead--Calcium Alloys;47 7.5;Lead--Calcium--Tin Alloys;48 7.5.1;Grain structure;48 7.5.2;Mechanical properties of cast lead–calcium&ndashtin alloys49 7.5.3;Aluminium addition;51 7.5.4;Tin effects on conductivity of battery grids;52 7.6;Lead--Antimony--Cadmium Alloys;59 7.7;References;59 8;3 Formation of Lead--acid Batteries and Structure of Positive and Negative Active Masses;64 8.1;Introduction;64 8.1.1;Manufacture of lead--acid battery plates;64 8.1.2;Survey of soaking and formation phenomena;67 8.2;Soaking of Plates;69 8.2.1;Filling VRLA cells with H2SO4 solution;69 8.2.2;Chemical zonal processes during soaking;71 8.2.3;Soaking of 3BS-cured pastes;73 8.2.4;Soaking of 4BS-cured pastes;79 8.3;Formation of Positive Plates;81 8.3.1;Thermodynamics of formation processes;81 8.3.2;Reactions during formation of PAM from 3BS-cured pastes;82 8.3.3;Zonal processes during formation of PAM from 3BS-cured pastes;86 8.3.4;beta-PbO2:alpha-PbO2 ratio and its effect on capacity of positive plates;89 8.3.5;Structure of PAM;91 8.3.6;Gel--crystal forms of PbO2 particles;93 8.3.7;Mechanism of formation of PbO2 particles;97 8.3.8;Formation of pore system in PAM and its functions;98 8.3.9;Influence of basic lead sulfates on cycle-life of positive plates;103 8.3.10;Formation of plates prepared with 4BS-cured pastes;106 8.3.11;Influence of current-collector surface
on formation of PbSO4 crystals at grid--PAM interface;110 8.4;Formation of Negative Plates;112 8.4.1;Thermodynamics of formation processes;112 8.4.2;Reactions during formation of negative plate;113 8.4.3;Zonal processes;115 8.4.4;Structure of negative active mass;118 8.4.5;Evolution of pore structure of plate during formation;121 8.4.6;Effect of expanders on NAM;123 8.4.7;Effect of expander structure on battery performance;126 8.5;Technology of Formation;127 8.5.1;Technological parameters of formation process;127 8.5.2;Stages of formation of positive and negative plates;127 8.5.3;General current (voltage) algorithm for formation of positive plates;130 8.6;Conclusions;133 8.7;References;134 9;4 Positive-Plate Additives to Enhance Formation and Battery Performance;136 9.1;Introduction;136 9.2;Modelling the Effects of Additives;136 9.3;Non-conductive Additives;138 9.3.1;Hollow glass microspheres;138 9.3.2;Carboxymethyl cellulose;139 9.3.3;Silica gel;140 9.3.4;Designer additives;140 9.4;Conductive Additives;141 9.4.1;Barium plumbate;142 9.4.2;Titanium oxide;145 9.4.3;Conductive polymers;146 9.4.4;SnO2;147 9.4.5;Iron boride;147 9.4.6;Lead-coated glass wire;147 9.4.7;Carbon;148 9.4.8;Lead dioxide;150 9.5;Chemically Active Additives;151 9.5.1;Sulfate salts;151 9.5.2;Phosphates;154 9.5.3;Bismuth;157 9.5.4;Polyvinylsulfonic acid and its salts;158 9.6;Conclusions;158 9.7;References;159 10;5 Negative Plates in Valve-regulated Lead--acid Batteries;162 10.1;Introduction;162 10.2;Basic Electrochemical Characteristics;163 10.3;Negative-plate Additives;169 10.3.1;Carbon;171 10.3.2;Barium sulfate;173 10.3.3;Organic additives;174 10.4;Charging Influences;181 10.5;Use of Internal Catalysts;184 10.6;Summary;186 10.7;References;187 11;6 The Function of the Separator in the Valve-regulated Lead--acid Battery;190 11.1;Introduction;190 11.2;Characteristics of Absorptive Glass Mat (AGM);191 11.2.1;Wetting behaviour of AGM materials;191 11.2.2;Physical properties of AGM materials;198 11.3;Ge
l Batteries;200 11.4;Separator Properties and Function;201 11.4.1;Compression characteristics;201 11.4.2;Oxygen cycle and recombination efficiency;203 11.4.3;Stratification and drainage;205 11.5;Future Developments;206 11.6;References;207 12;7 Separator Materials for Valve-regulated Lead--acid Batteries;210 12.1;Introduction;210 12.2;State-of-the-art Separators;210 12.2.1;Absorptive glass mat (AGM) separators;210 12.2.2;Separators for gel batteries;212 12.3;Development Trends for VRLA Battery Separators;213 12.4;Separator Developments;214 12.4.1;Modified AGM;214 12.4.2;Alternative separators;222 12.5;Conclusions;230 12.6;References;230 13;8 Battery Management;234 13.1;Introduction;234 13.2;Tasks of Battery Management Systems;235 13.3;Designs of Battery Management System;236 13.4;Battery Data Acquisition;237 13.5;Determination of Battery State;239 13.5.1;Battery state-of-charge;240 13.5.2;Battery state-of-health;252 13.6;Electrical Management of Batteries;256 13.6.1;Control of charge;256 13.6.2;Control of discharge;256 13.6.3;Multiple battery systems;258 13.7;Thermal Management of Batteries;260 13.7.1;Air systems;260 13.7.2;Liquid systems;261 13.7.3;Electrical systems;262 13.7.4;Passive cooling systems and isolation;263 13.7.5;Phase-change materials;264 13.7.6;Other systems;264 13.8;Storage of Historical Battery Data;264 13.9;Safety Management of Batteries;265 13.10;System Communications;265 13.11;Conclusions;266 13.12;References;266 14;9 Charging Techniques for VRLA Batteries;268 14.1;Introduction;268 14.1.1;Basic charging — chemistry&solsecondary reactions269 14.1.2;Traditional charging methods;272 14.2;Charging of VRLA Products;281 14.2.1;The oxygen cycle and saturation effects;281 14.2.2;Gas transport and oxygen cycle;284 14.2.3;Overcharge processes;286 14.3;Existing Charging Methods Applied to VRLA Products;289 14.3.1;Float charging;289 14.3.2;Cyclic charging;294 14.3.3;Fast charging;298 14.3.4;Charge-termination strategies;299 14.3.5;Failure modes attribu
table to charging;301 14.4;Evolving and Optimized Charging Methods;303 14.4.1;Optimized approaches to float charging;303 14.4.2;Optimized approaches to cyclic charging;306 14.4.3;Partial-state-of-charge cycling — an evolving algorithm312 14.5;Summary and Conclusions;315 14.6;References;318 15;10 Battery Energy-Storage Systems for Power-Supply Networks;322 15.1;Introduction;322 15.2;A Historical Perspective;322 15.3;Energy-Storage Technologies;324 15.3.1;Lead–acid (and advanced) batteries328 15.3.2;Supercapacitors;328 15.3.3;Flywheels;329 15.3.4;Superconducting magnetic energy storage;329 15.4;Energy-storage Applications;329 15.4.1;Rapid reserve (generation);331 15.4.2;Area control and frequency responsive reserve (generation);331 15.4.3;Commodity storage (generation);332 15.4.4;Transmission system stability (T&D)332 15.4.5;Transmission voltage regulation (T&D)332 15.4.6;Transmission facility deferral (T&D)332 15.4.7;Distribution facility deferral (T&D)332 15.4.8;Renewable energy management (customer service);333 15.4.9;Customer energy management (customer service);333 15.4.10;Power quality and reliability (customer service);333 15.5;Battery Energy-storage Systems;333 15.5.1;Elektrizitätswerk Hammermuehle, Germany333 15.5.2;BEWAG AG, Berlin, Germany;335 15.5.3;Hagen Batterie AG, Soest, Germany;336 15.5.4;Crescent Electric Membership Corporation, Statesville, NC, USA;336 15.5.5;Southern California Edison, Chino, CA, USA;337 15.5.6;Johnson Controls, Inc., Milwaukee, WI, USA;338 15.5.7;Puerto Rico Electric Power Authority;339 15.5.8;GNB Technologies, Vernon, CA, USA;340 15.5.9;Metlakatla, AK, USA;341 15.5.10;Herne and Bochold, Germany;342 15.5.11;PQ2000;343 15.6;Power Conversion;344 15.6.1;Basic concepts;345 15.6.2;Switch considerations;348 15.6.3;Performance issues;348 15.7;Cost Considerations;349 15.8;Concluding Remarks;350 15.9;References;352 16;11 Valve-regulated Lead---acid Batteries in Automotive Applications --- A Vehicle Manufact
urers Perspective;354 16.1;Introduction;354 16.1.1;Battery selection process;355 16.1.2;Sub-system description;360 16.1.3;Initial design phase;362 16.1.4;Failure modes and effects analysis;362 16.1.5;Design validation plan;364 16.1.6;Future electric loads;364 16.1.7;Environmental;369 16.1.8;Cost;370 16.1.9;Reliability;371 16.1.10;Safety;373 16.1.11;Maintenance-free;373 16.1.12;Weight savings;374 16.2;VRLA in Automotive Applications;374 16.2.1;VRLA features of interest to the automotive industry;375 16.2.2;Continuum of electric drive;378 16.3;Automotive Applications;380 16.3.1;12-V automotive;380 16.3.2;42-V automotive;390 16.3.3;Soft hybrids;396 16.3.4;Parallel–series hybrids405 16.3.5;Electric vehicles;412 16.4;Conclusions;423 16.5;References;423 17;12 Valve-regulated Lead--acid Batteries in Automotive Applications --- A Battery Manufacturers Perspective;424 17.1;Introduction;424 17.2;History of Automotive Batteries and Vehicle Electrical Systems;428 17.2.1;The beginning;428 17.2.2;Development of vehicle electrical power systems and automotive batteries in 20th century;428 17.2.3;Expected changes in vehicle electrical systems in next decade and corresponding demands on automotive batteries;434 17.3;Design, Components, Manufacturing of Automotive Batteries;436 17.3.1;Components;436 17.3.2;Special designs/special applications436 17.3.3;Plate arrangement — plate stacking and spiral winding437 17.3.4;AGM and gel technology in vehicles;440 17.3.5;VRLA automotive 12-V batteries for standard vehicle electrical systems;441 17.3.6;36-V VRLA automotive batteries for 42-V PowerNets;442 17.4;The VRLA Battery in Automotive Applications and its Interaction with the Vehicle;444 17.4.1;VRLA batteries in present vehicle electric systems;444 17.4.2;VRLA batteries in vehicles with new components and new operating strategies;447 17.4.3;State-detection and management of VRLA batteries;453 17.5;Performance Data;454 17.6;Outlook;454 17.7;References;457 18;13 Valve-regulat
ed Lead--acid Batteries for Telecommunications and UPS Applications;462 18.1;Introduction;462 18.2;Features of VRLA Technology;463 18.2.1;Positive-grid corrosion;463 18.2.2;Improvement of service-life;467 18.3;Gel Batteries;473 18.4;AGM Batteries;478 18.5;Large Batteries for Stationary Applications;482 18.6;Future Trends in Stand-by Batteries;486 18.6.1;Continuous plate-processing;486 18.6.2;Spiral technology;488 18.6.3;Advanced separators;489 18.7;Conclusions;489 18.8;References;490 19;14 Remote-area Power-supply (RAPS) Systems and the Valve-regulated Lead--acid Battery;494 19.1;The Need for Remote-area Power-supply Systems;494 19.2;RAPS System Components;494 19.2.1;Battery bank;495 19.2.2;Diesel generator;496 19.2.3;Photovoltaic array;496 19.2.4;Wind generator;497 19.2.5;Hydro-generator;497 19.2.6;Inverter;498 19.2.7;Control system;499 19.3;RAPS System Design;499 19.3.1;Direct-current RAPS systems;500 19.3.2;Alternating-current RAPS systems;501 19.4;VRLA Batteries for RAPS Systems;503 19.4.1;Advantages;503 19.4.2;Disadvantages;504 19.4.3;Failure modes;505 19.4.4;Preferred design features;509 19.4.5;Recent developments;511 19.4.6;Advanced operating strategies;511 19.5;References;516 20;15 Recovery and Recycling of Lead--acid Batteries;518 20.1;Introduction;518 20.2;Battery Collection and Processing;519 20.2.1;Battery collection;519 20.2.2;Battery processing;520 20.3;Recovery and Refining;523 20.3.1;Pyrometallurgical methods;523 20.3.2;Hydrometallurgical methods;530 20.3.3;Refining and alloying of lead;530 20.4;Challenges Facing the Secondary Lead Industry;535 20.4.1;Processing and recovery;535 20.4.2;Refining;536 20.4.3;Silver;536 20.4.4;Antimony;537 20.4.5;Catalyst elements;537 20.4.6;Other elements;538 20.5;References;538 21;16 Environmental Aspects of Recycling Valve-regulated Lead--acid Batteries;540 21.1;Introduction;540 21.2;Justification for Recycling;541 21.3;Recycling Rates;542 21.4;Collection of Used VRLA Batteries;542 21.5;Transport of Used VRLA Batterie
s;544 21.6;Recycling Process;546 21.7;Recycling Options;549 21.8;Monitoring and Controlling Emissions;553 21.9;Engineering Control in the Workplace;554 21.10;Process Emission Controls;555 21.11;Emission Testing and Analysis;556 21.12;Biological Monitoring;559 21.13;Respiratory Protection;561 21.14;Employees’ Amenities564 21.14.1;Location;564 21.14.2;Segregation;565 21.14.3;Containment;565 21.15;Effluent Control;566 21.16;International Conventions and Protocols;570 21.16.1;Basel Convention;570 21.17;Appendix 1;571 21.18;References;574 22;17 The Next Great Challenge for Valve-regulated Lead--acid Batteries: High-rate Partial-state-of-charge Duty in New-generation Roa;576 22.1;Future Automobile Electrical Systems;576 22.2;The Challenge of High-rate Partial-state-of-charge (HRPSoC) Duty;577 22.3;Mechanism of Lead Sulfate Accumulation During HRPSoC Duty;581 22.4;Controlling Secondary Reactions During High-rate Charge;586 22.4.1;Trace element control;586 22.4.2;Separator design;586 22.4.3;Carbon inventory;586 22.5;Grid Design for HRPSoC Duty;587 22.6;The Role of Plate Thickness;589 22.7;Concluding Remarks;591 22.8;References;592 23;Subject Index;594