An ideal text for students as well as practitioners, this is a comprehensive introduction to the field of scanning electron microscopy (SEM) and X-ray microanalysis. The authors emphasize the practical aspects of the techniques described.
In the decade since the publication of the second edition of Scanning Electron Microscopy and X-Ray Microanalysis, there has been a great expansion in the capabilities of the basic scanning electron microscope (SEM) and the x-ray spectrometers. The emergence of the variab- pressure/environmental SEM has enabled the observation of samples c- taining water or other liquids or vapor and has allowed for an entirely new class of dynamic experiments, that of direct observation of che- cal reactions in situ. Critical advances in electron detector technology and computer-aided analysis have enabled structural (crystallographic) analysis of specimens at the micrometer scale through electron backscatter diffr- tion (EBSD). Low-voltage operation below 5 kV has improved x-ray spatial resolution by more than an order of magnitude and provided an effective route to minimizing sample charging. High-resolution imaging has cont- ued to develop with a more thorough understanding of how secondary el- trons are generated. The ? eld emission gun SEM, with its high brightness, advanced electron optics, which minimizes lens aberrations to yield an - fective nanometer-scale beam, and "through-the-lens" detector to enhance the measurement of primary-beam-excited secondary electrons, has made high-resolution imaging the rule rather than the exception. Methods of x-ray analysis have evolved allowing for better measurement of specimens with complex morphology: multiple thin layers of different compositions, and rough specimens and particles. Digital mapping has transformed classic x-ray area scanning, a purely qualitative technique, into fully quantitative compositional mapping.
Inhaltsverzeichnis
1. Introduction. - 1. 1. Imaging Capabilities. - 1. 2. Structure Analysis. - 1. 3. Elemental Analysis. - 1. 4. Summary and Outline of This Book. - Appendix A. Overview of Scanning Electron Microscopy. - Appendix B. Overview of Electron Probe X-Ray Microanalysis. - References. - 2. The SEM and Its Modes of Operation. - 2. 1. How the SEM Works. - 2. 1. 1. Functions of the SEM Subsystems. - 2. 1. 1. 1. Electron Gun and Lenses Produce a Small Electron Beam. - 2. 1. 1. 2. Deflection System Controls Magnification. - 2. 1. 1. 3. Electron Detector Collects the Signal. - 2. 1. 1. 4. Camera or Computer Records the Image. - 2. 1. 1. 5. Operator Controls. - 2. 1. 2. SEM Imaging Modes. - 2. 1. 2. 1. Resolution Mode. - 2. 1. 2. 2. High-Current Mode. - 2. 1. 2. 3. Depth-of-Focus Mode. - 2. 1. 2. 4. Low-Voltage Mode. - 2. 1. 3. Why Learn about Electron Optics? . - 2. 2. Electron Guns. - 2. 2. 1. Tungsten Hairpin Electron Guns. - 2. 2. 1. 1. Filament. - 2. 2. 1. 2. Grid Cap. - 2. 2. 1. 3. Anode. - 2. 2. 1. 4. Emission Current and Beam Current. - 2. 2. 1. 5. Operator Control of the Electron Gun. - 2. 2. 2. Electron Gun Characteristics. - 2. 2. 2. 1. Electron Emission Current. - 2. 2. 2. 2. Brightness. - 2. 2. 2. 3. Lifetime. - 2. 2. 2. 4. Source Size, Energy Spread, Beam Stability. - 2. 2. 2. 5. Improved Electron Gun Characteristics. - 2. 2. 3. Lanthanum Hexaboride (LaB6) Electron Guns. - 2. 2. 3. 1. Introduction. - 2. 2. 3. 2. Operation of the LaB6 Source. - 2. 2. 4. Field Emission Electron Guns. - 2. 3. Electron Lenses. - 2. 3. 1. Making the Beam Smaller. - 2. 3. 1. 1. Electron Focusing. - 2. 3. 1. 2. Demagnification of the Beam. - 2. 3. 2. Lenses in SEMs. - 2. 3. 2. 1. Condenser Lenses. - 2. 3. 2. 2. Objective Lenses. - 2. 3. 2. 3. Real and Virtual Objective Apertures. - 2. 3. 3. Operator Control of SEM Lenses. - 2. 3. 3. 1. Effect of Aperture Size. - 2. 3. 3. 2. Effect of Working Distance. - 2. 3. 3. 3. Effect of Condenser Lens Strength. - 2. 3. 4. Gaussian Probe Diameter. - 2. 3. 5. Lens Aberrations. - 2. 3. 5. 1. Spherical Aberration. - 2. 3. 5. 2. Aperture Diffraction. - 2. 3. 5. 3. Chromatic Aberration. - 2. 3. 5. 4. Astigmatism. - 2. 3. 5. 5. Aberrations in theObjective Lens. - 2. 4. Electron Probe Diameter versus Electron Probe Current. - 2. 4. 1. Calculation of dmin and imax. - 2. 4. 1. 1. Minimum Probe Size. - 2. 4. 1. 2. Minimum Probe Size at 10-30 kV. - 2. 4. 1. 3. Maximum Probe Current at 10-30 kV. - 2. 4. 1. 4. Low-Voltage Operation. - 2. 4. 1. 5. Graphical Summary. - 2. 4. 2. Performance in the SEM Modes. - 2. 4. 2. 1. Resolution Mode. - 2. 4. 2. 2. High-Current Mode. - 2. 4. 2. 3. Depth-of-Focus Mode. - 2. 4. 2. 4. Low-Voltage SEM. - 2. 4. 2. 5. Environmental Barriers to High-Resolution Imaging. - References. - 3. Electron Beam Specimen Interactions. - 3. 1. The Story So Far. - 3. 2. The Beam Enters the Specimen. - 3. 3. The Interaction Volume. - 3. 3. 1. Visualizing the Interaction Volume. - 3. 3. 2. Simulating the Interaction Volume. - 3. 3. 3. Influence of Beam and Specimen Parameters on the Interaction Volume. - 3. 3. 3. 1. Influence of Beam Energy on the Interaction Volume. - 3. 3. 3. 2. Influence of Atomic Number on the Interaction Volume. - 3. 3. 3. 3. Influence of Specimen Surface Tilt on the Interaction Volume. - 3. 3. 4. Electron Range: A Simple Measure of the Interaction Volume. - 3. 3. 4. 1. Introduction. - 3. 3. 4. 2. The Electron Range at Low Beam Energy. - 3. 4. Imaging Signals from the Interaction Volume. - 3. 4. 1. Backscattered Electrons. - 3. 4. 1. 1. Atomic Number Dependence of BSE. - 3. 4. 1. 2. Beam Energy Dependence of BSE. - 3. 4. 1. 3. Tilt Dependence of BSE. - 3. 4. 1. 4. Angular Distribution of BSE. - 3. 4. 1. 5. Energy Distribution of BSE. - 3. 4. 1. 6. Lateral Spatial Distribution of BSE. - 3. 4. 1. 7. Sampling Depth of BSE. - 3. 4. 2. Secondary Electrons. - 3. 4. 2. 1. Definition and Origin of SE. - 3. 4. 2. 2. SE Yield with Primary Beam Energy. - 3. 4. 2. 3. SE Energy Distribution. - 3. 4. 2. 4. Range and Escape Depth of SE. - 3. 4. 2. 5. Relative Contributions of SE1 and SE2. - 3. 4. 2. 6. Specimen Composition Dependence of SE. - 3. 4. 2. 7. Specimen Tilt Dependence of SE. - 3. 4. 2. 8. Angular Distribution of SE. - References. - 4. Image Formation and Interpretation. - 4. 1. The Story So Far. - 4. 2. The Basic SEM Imaging Process. - 4. 2. 1. Scanning Action. - 4. 2. 2. Image Construction (Mapping). - 4. 2. 2. 1. Line Scans. - 4. 2. 2. 2. Image (Area) Scanning. - 4. 2. 2. 3. Digital Imaging: Collection and Display. - 4. 2. 3. Magnification. - 4. 2. 4. Picture Element (Pixel) Size. - 4. 2. 5. Low-Magnification Operation. - 4. 2. 6. Depth of Field (Focus). - 4. 2. 7. Image Distortion. - 4. 2. 7. 1. Projection Distortion: Gnomonic Projection. - 4. 2. 7. 2. Projection Distortion: Image Foreshortening. - 4. 2. 7. 3. Scan Distortion: Pathological Defects. - 4. 2. 7. 4. Moiré Effects. - 4. 3. Detectors. - 4. 3. 1. Introduction. - 4. 3. 2. Electron Detectors. - 4. 3. 2. 1. Everhart Thornley Detector. - 4. 3. 2. 2. Through-the-Lens (TTL) Detector. - 4. 3. 2. 3. Dedicated Backscattered Electron Detectors. - 4. 4. The Roles of the Specimen and Detector in Contrast Formation. - 4. 4. 1. Contrast. - 4. 4. 2. Compositional (Atomic Number) Contrast. - 4. 4. 2. 1. Introduction. - 4. 4. 2. 2. Compositional Contrast with Backscattered Electrons. - 4. 4. 3. Topographic Contrast. - 4. 4. 3. 1. Origins of Topographic Contrast. - 4. 4. 3. 2. Topographic Contrast with the Everhart Thornley Detector. - 4. 4. 3. 3. Light-Optical Analogy. - 4. 4. 3. 4. Interpreting Topographic Contrast with Other Detectors. - 4. 5. Image Quality. - 4. 6. Image Processing for the Display of Contrast Information. - 4. 6. 1. The Signal Chain. - 4. 6. 2. The Visibility Problem. - 4. 6. 3. Analog and Digital Image Processing. - 4. 6. 4. Basic Digital Image Processing. - 4. 6. 4. 1. Digital Image Enhancement. - 4. 6. 4. 2. Digital Image Measurements. - References. - 5. Special Topics in Scanning Electron Microscopy. - 5. 1. High-Resolution Imaging. - 5. 1. 1. The Resolution Problem. - 5. 1. 2. Achieving High Resolution at High Beam Energy. - 5. 1. 3. High-Resolution Imaging at Low Voltage. - 5. 2. STEM-in-SEM: High Resolution for the Special Case of Thin Specimens. - 5. 3. Surface Imaging at Low Voltage. - 5. 4. Making Dimensional Measurements in the SEM. - 5. 5. Recovering the Third Dimension: Stereomicroscopy. - 5. 5. 1. Qualitative Stereo Imaging and Presentation. - 5. 5. 2. Quantitative Stereo Microscopy. - 5. 6. Variable-Pressure and Environmental SEM. - 5. 6. 1. Current Instruments. - 5. 6. 2. Gas in the Specimen Chamber. - 5. 6. 2. 1. Units of Gas Pressure. - 5. 6. 2. 2. The Vacuum System. - 5. 6. 3. Electron Interactions with Gases. - 5. 6. 4. The Effect of the Gas on Charging. - 5. 6. 5. Imaging in the ESEM and the VPSEM. - 5. 6. 6. X-Ray Microanalysis in the Presence of a Gas. - 5. 7. Special Contrast Mechanisms. - 5. 7. 1. Electric Fields. - 5. 7. 2. Magnetic Fields. - 5. 7. 2. 1. Type 1 Magnetic Contrast. - 5. 7. 2. 2. Type 2 Magnetic Contrast. - 5. 7. 3. Crystallographic Contrast. - 5. 8. Electron Backscatter Patterns. - 5. 8. 1. Origin of EBSD Patterns. - 5. 8. 2. Hardware for EBSD. - 5. 8. 3. Resolution of EBSD. - 5. 8. 3. 1. Lateral Spatial Resolution. - 5. 8. 3. 2. Depth Resolution. - 5. 8. 4. Applications. - 5. 8. 4. 1. Orientation Mapping. - 5. 8. 4. 2. Phase Identification. - References. - 6. Generation of X-Rays in the SEM Specimen. - 6. 1. Continuum X-Ray Production (Bremsstrahlung). - 6. 2. Characteristic X-Ray Production. - 6. 2. 1. Origin. - 6. 2. 2. Fluorescence Yield. - 6. 2. 3. Electron Shells. - 6. 2. 4. Energy-Level Diagram. - 6. 2. 5. Electron Transitions. - 6. 2. 6. Critical Ionization Energy. - 6. 2. 7. Moseley s Law. - 6. 2. 8. Families of Characteristic Lines. - 6. 2. 9. Natural Width of Characteristic X-Ray Lines. - 6. 2. 10. Weights of Lines. - 6. 2. 11. Cross Section for Inner Shell Ionization. - 6. 2. 12. X-Ray Production in Thin Foils. - 6. 2. 13. X-Ray Production in Thick Targets. - 6. 2. 14. X-Ray Peak-to-Background Ratio. - 6. 3. Depth of X-Ray Production (X-Ray Range). - 6. 3. 1. Anderson Hasler X-Ray Range. - 6. 3. 2. X-Ray Spatial Resolution. - 6. 3. 3. Sampling Volume and Specimen Homogeneity. - 6. 3. 4. Depth Distribution of X-Ray Production, ? (? z). - 6. 4. X-Ray Absorption. - 6. 4. 1. Mass Absorption Coefficient for an Element. - 6. 4. 2. Effect of Absorption Edge on Spectrum. - 6. 4. 3. Absorption Coefficient for Mixed-Element Absorbers. - 6. 5. X-Ray Fluorescence. - 6. 5. 1. Characteristic Fluorescence. - 6. 5. 2. Continuum Fluorescence. - 6. 5. 3. Range of Fluorescence Radiation. - References. - 7. X-Ray Spectral Measurement: EDS and WDS. - 7. 1. Introduction. - 7. 2. Energy-Dispersive X-Ray Spectrometer. - 7. 2. 1. Operating Principles. - 7. 2. 2. The Detection Process. - 7. 2. 3. Charge-to-Voltage Conversion. - 7. 2. 4. Pulse-Shaping Linear Amplifier and Pileup Rejection Circuitry. - 7. 2. 5. The Computer X-Ray Analyzer. - 7. 2. 6. Digital Pulse Processing. - 7. 2. 7. Spectral Modification Resulting from the Detection Process. - 7. 2. 7. 1. Peak Broadening. - 7. 2. 7. 2. Peak Distortion. - 7. 2. 7. 3. Silicon X-Ray Escape Peaks. - 7. 2. 7. 4. Absorption Edges. - 7. 2. 7. 5. Silicon Internal Fluorescence Peak. - 7. 2. 8. Artifacts from the Detector Environment. - 7. 2. 9. Summary of EDS Operation and Artifacts. - 7. 3. Wavelength-Dispersive Spectrometer. - 7. 3. 1. Introduction. - 7. 3. 2. Basic Description. - 7. 3. 3. Diffraction Conditions. - 7. 3. 4. Diffracting Crystals. - 7. 3. 5. The X-Ray Proportional Counter. - 7. 3. 6. Detector Electronics. - 7. 4. Comparison of Wavelength-Dispersive Spectrometers with Conventional Energy-Dispersive Spectrometers. - 7. 4. 1. Geometric Collection Efficiency. - 7. 4. 2. Quantum Efficiency. - 7. 4. 3. Resolution. - 7. 4. 4. Spectral Acceptance Range. - 7. 4. 5. Maximum Count Rate. - 7. 4. 6. Minimum Probe Size. - 7. 4. 7. Speed of Analysis. - 7. 4. 8. Spectral Artifacts. - 7. 5. Emerging Detector Technologies. - 7. 5. 1. X-Ray Microcalorimetery. - 7. 5. 2. Silicon Drift Detectors. - 7. 5. 3. Parallel Optic Diffraction-Based Spectrometers. - References. - 8. Qualitative X-Ray Analysis. - 8. 1. Introduction. - 8. 2. EDS Qualitative Analysis. - 8. 2. 1. X-Ray Peaks. - 8. 2. 2. Guidelines for EDS Qualitative Analysis. - 8. 2. 2. 1. General Guidelines for EDS Qualitative Analysis. - 8. 2. 2. 2. Specific Guidelines for EDS Qualitative Analysis. - 8. 2. 3. Examples of Manual EDS Qualitative Analysis. - 8. 2. 4. Pathological Overlaps in EDS Qualitative Analysis. - 8. 2. 5. Advanced Qualitative Analysis: Peak Stripping. - 8. 2. 6. Automatic Qualitative EDS Analysis. - 8. 3. WDS Qualitative Analysis. - 8. 3. 1. Wavelength-Dispersive Spectrometry of X-Ray Peaks. - 8. 3. 2. Guidelines for WDS Qualitative Analysis. - References. - 9. Quantitative X-Ray Analysis: The Basics. - 9. 1. Introduction. - 9. 2. Advantages of Conventional Quantitative X-Ray Microanalysis in the SEM. - 9. 3. Quantitative Analysis Procedures: Flat-Polished Samples. - 9. 4. The Approach to X-Ray Quantitation: The Need for Matrix Corrections. - 9. 5. The Physical Origin of Matrix Effects. - 9. 6. ZAF Factors in Microanalysis. - 9. 6. 1. Atomic number effect, Z. - 9. 6. 1. 1. Effect of Backscattering (R) and Energy Loss (S ). - 9. 6. 1. 2. X-Ray Generation with Depth, ? (? z). - 9. 6. 2. X-Ray Absorption Effect, A. - 9. 6. 3. X-Ray Fluorescence, F. - 9. 7. Calculation of ZAF Factors. - 9. 7. 1. Atomic Number Effect, Z. - 9. 7. 2. Absorption correction, A. - 9. 7. 3. Characteristic Fluorescence Correction, F. - 9. 7. 4. Calculation of ZAF. - 9. 7. 5. The Analytical Total. - 9. 8. Practical Analysis. - 9. 8. 1. Examples of Quantitative Analysis. - 9. 8. 1. 1. Al Cu Alloys. - 9. 8. 1. 2. Ni 10 wt% Fe Alloy. - 9. 8. 1. 3. Ni 38. 5 wt% Cr 3. 0 wt% Al Alloy. - 9. 8. 1. 4. Pyroxene: 53. 5 wt% SiO2, 1. 11 wt% Al2O3, 0. 62 wt% Cr2O3, 9. 5 wt% FeO, 14. 1 wt% MgO, and 21. 2 wt% CaO. - 9. 8. 2. Standardless Analysis. - 9. 8. 2. 1. First-Principles Standardless Analysis. - 9. 8. 2. 2. Fitted-Standards Standardless Analysis. - 9. 8. 3. Special Procedures for Geological Analysis. - 9. 8. 3. 1. Introduction. - 9. 8. 3. 2. Formulation of the Bence Albee Procedure. - 9. 8. 3. 3. Application of the Bence Albee Procedure. - 9. 8. 3. 4. Specimen Conductivity. - 9. 8. 4. Precision and Sensitivity in X-Ray Analysis. - 9. 8. 4. 1. Statistical Basis for Calculating Precision and Sensitivity. - 9. 8. 4. 2. Precision of Composition. - 9. 8. 4. 3. Sample Homogeneity. - 9. 8. 4. 4. Analytical Sensitivity. - 9. 8. 4. 5. Trace Element Analysis. - 9. 8. 4. 6. Trace Element Analysis Geochronologic Applications. - 9. 8. 4. 7. Biological and Organic Specimens. - References. - 10. Special Topics in Electron Beam X-Ray Microanalysis. - 10. 1. Introduction. - 10. 2. Thin Film on a Substrate. - 10. 3. Particle Analysis. -10. 3. 1. Particle Mass Effect. - 10. 3. 2. Particle Absorption Effect. - 10. 3. 3. Particle Fluorescence Effect. - 10. 3. 4. Particle Geometric Effects. - 10. 3. 5. Corrections for Particle Geometric Effects. - 10. 3. 5. 1. The Consequences of Ignoring Particle Effects. - 10. 3. 5. 2. Normalization. - 10. 3. 5. 3. Critical Measurement Issues for Particles. - 10. 3. 5. 4. Advanced Quantitative Methods for Particles. - 10. 4. Rough Surfaces. - 10. 4. 1. Introduction. - 10. 4. 2. Rough Specimen Analysis Strategy. - 10. 4. 2. 1. Reorientation. - 10. 4. 2. 2. Normalization. - 10. 4. 2. 3. Peak-to-Background Method. - 10. 5. Beam-Sensitive Specimens (Biological, Polymeric). - 10. 5. 1. Thin-Section Analysis. - 10. 5. 2. Bulk Biological and Organic Specimens. - 10. 6. X-Ray Mapping. - 10. 6. 1. Relative Merits of WDS and EDS for Mapping. - 10. 6. 2. Digital Dot Mapping. - 10. 6. 3. Gray-Scale Mapping. - 10. 6. 3. 1. The Need for Scaling in Gray-Scale Mapping. - 10. 6. 3. 2. Artifacts in X-Ray Mapping. - 10. 6. 4. Compositional Mapping. - 10. 6. 4. 1. Principles of Compositional Mapping. - 10. 6. 4. 2. Advanced Spectrum Collection Strategies for Compositional Mapping. - 10. 6. 5. The Use of Color in Analyzing and Presenting X-Ray\ Maps. - 10. 6. 5. 1. Primary Color Superposition. - 10. 6. 5. 2. Pseudocolor Scales. - 10. 7. Light Element Analysis. - 10. 7. 1. Optimization of Light Element X-Ray Generation. - 10. 7. 2. X-Ray Spectrometry of the Light Elements. - 10. 7. 2. 1. Si EDS. - 10. 7. 2. 2. WDS. - 10. 7. 3. Special Measurement Problems for the Light Elements. - 10. 7. 3. 1. Contamination. - 10. 7. 3. 2. Overvoltage Effects. - 10. 7. 3. 3. Absorption Effects. - 10. 7. 4. Light Element Quantification. - 10. 8. Low-Voltage Microanalysis. - 10. 8. 1. Low-Voltage versus Conventional Microanalysis. - 10. 8. 2. X-Ray Production Range. - 10. 8. 2. 1. Contribution of the Beam Size to the X-Ray Analytical Resolution. - 10. 8. 2. 2. A Consequence of the X-Ray Range under Low-Voltage Conditions. - 10. 8. 3. X-Ray Spectrometry in Low-Voltage Microanalysis. - 10. 8. 3. 1. The Oxygen and Carbon Problem. - 10. 8. 3. 2. Quantitative X-Ray Microanalysis at Low Voltage. - 10. 9. Report of Analysis. - References. - 11. Specimen Preparation of Hard Materials: Metals, Ceramics, Rocks, Minerals, Microelectronic and Packaged Devices, Particles, and Fibers. - 11. 1. Metals. - 11. 1. 1. Specimen Preparation for Surface Topography. - 11. 1. 2. Specimen Preparation for Microstructural and Microchemical Analysis. - 11. 1. 2. 1. Initial Sample Selection and Specimen Preparation Steps. - 11. 1. 2. 2. Final Polishing Steps. - 11. 1. 2. 3. Preparation for Microanalysis. - 11. 2. Ceramics and Geological Samples. - 11. 2. 1. Initial Specimen Preparation: Topography and Microstructure. - 11. 2. 2. Mounting and Polishing for Microstructural and Microchemical Analysis. - 11. 2. 3. Final Specimen Preparation for Microstructural and Microchemical Analysis. - 11. 3. Microelectronics and Packages. - 11. 3. 1. Initial Specimen Preparation. - 11. 3. 2. Polishing. - 11. 3. 3. Final Preparation. - 11. 4. Imaging of Semiconductors. - 11. 4. 1. Voltage Contrast. - 11. 4. 2. Charge Collection. - 11. 5. Preparation for Electron Diffraction in the SEM. - 11. 5. 1. Channeling Patterns and Channeling Contrast. - 11. 5. 2. Electron Backscatter Diffraction. - 11. 6. Special Techniques. - 11. 6. 1. Plasma Cleaning. - 11. 6. 2. Focused-Ion-Beam Sample Preparation for SEM. - 11. 6. 2. 1. Application of FIB for Semiconductors. - 11. 6. 2. 2. Applications of FIB in Materials Science. - 11. 7. Particles and Fibers. - 11. 7. 1. Particle Substrates and Supports. - 11. 7. 1. 1. Bulk Particle Substrates. - 11. 7. 1. 2. Thin Particle Supports. - 11. 7. 2. Particle Mounting Techniques. - 11. 7. 3. Particles Collected on Filters. - 11. 7. 4. Particles in a Solid Matrix. - 11. 7. 5. Transfer of Individual Particles. - References. - 12. Specimen Preparation of Polymer Materials. - 12. 1. Introduction. - 12. 2. Microscopy of Polymers. - 12. 2. 1. Radiation Effects. - 12. 2. 2. Imaging Compromises. - 12. 2. 3. Metal Coating Polymers for Imaging. - 12. 2. 4. X-Ray Microanalysis of Polymers. - 12. 3. Specimen Preparation Methods for Polymers. - 12. 3. 1. Simple Preparation Methods. - 12. 3. 2. Polishing of Polymers. - 12. 3. 3. Microtomy of Polymers. - 12. 3. 4. Fracture of Polymer Materials. - 12. 3. 5. Staining of Polymers. - 12. 3. 5. 1. Osmium Tetroxide and Ruthenium Tetroxide. - 12. 3. 5. 2. Ebonite. - 12. 3. 5. 3. Chlorosulfonic Acid and Phosphotungstic Acid. - 12. 3. 6. Etching of Polymers. - 12. 3. 7. Replication of Polymers. - 12. 3. 8. Rapid Cooling and Drying Methods for Polymers. - 12. 3. 8. 1. Simple Cooling Methods. - 12. 3. 8. 2. Freeze-Drying. - 12. 3. 8. 3. Critical-Point Drying. - 12. 4. Choosing Specimen Preparation Methods. - 12. 4. 1. Fibers. - 12. 4. 2. Films and Membranes. - 12. 4. 3. Engineering Resins and Plastics. - 12. 4. 4. Emulsions and Adhesives. - 12. 5. Problem-Solving Protocol. - 12. 6. Image Interpretation and Artifacts. - References. - 13. Ambient-Temperature Specimen Preparation of Biological Material. - 13. 1. Introduction. - 13. 2. Preparative Procedures for the Structural SEM of Single Cells, Biological Particles, and Fibers. - 13. 2. 1. Particulate, Cellular, and Fibrous Organic Material. -13. 2. 2. Dry Organic Particles and Fibers. - 13. 2. 2. 1. Organic Particles and Fibers on a Filter. - 13. 2. 2. 2. Organic Particles and Fibers Entrained within a Filter. - 13. 2. 2. 3. Organic Particulate Matter Suspended in a Liquid. - 13. 2. 2. 4. Manipulating Individual Organic Particles. - 13. 3. Preparative Procedures for the Structural Observation of Large Soft Biological Specimens. - 13. 3. 1. Introduction. - 13. 3. 2. Sample Handling before Fixation. - 13. 3. 3. Fixation. - 13. 3. 4. Microwave Fixation. - 13. 3. 5. Conductive Infiltration. - 13. 3. 6. Dehydration. - 13. 3. 7. Embedding. - 13. 3. 8. Exposing the Internal Contents of Bulk Specimens. - 13. 3. 8. 1. Mechanical Dissection. - 13. 3. 8. 2. High-Energy-Beam Surface Erosion. - 13. 3. 8. 3. Chemical Dissection. - 13. 3. 8. 4. Surface Replicas and Corrosion Casts. - 13. 3. 9. Specimen Supports and Methods of Sample Attachment. - 13. 3. 10. Artifacts. - 13. 4. Preparative Procedures for the in Situ Chemical Analysis of Biological Specimens in the SEM. - 13. 4. 1. Introduction. - 13. 4. 2. Preparative Procedures for Elemental Analysis Using X-Ray Microanalysis. - 13. 4. 2. 1. The Nature and Extent of the Problem. - 13. 4. 2. 2. Types of Sample That May be Analyzed. - 13. 4. 2. 3. The General Strategy for Sample Preparation. - 13. 4. 2. 4. Criteria for Judging Satisfactory Sample Preparation. - 13. 4. 2. 5. Fixation and Stabilization. - 13. 4. 2. 6. Precipitation Techniques. - 13. 4. 2. 7. Procedures for Sample Dehydration, Embedding, and Staining. - 13. 4. 2. 8. Specimen Supports. - 13. 4. 3. Preparative Procedures for Localizing Molecules Using Histochemistry. - 13. 4. 3. 1. Staining and Histochemical Methods. - 13. 4. 3. 2. Atomic Number Contrast with Backscattered Electrons. - 13. 4. 4. Preparative Procedures for Localizing Macromolecues Using Immunocytochemistry. - 13. 4. 4. 1. Introduction. - 13. 4. 4. 2. The Antibody Antigen Reaction. - 13. 4. 4. 3. General Features of Specimen Preparation for Immunocytochemistry. - 13. 4. 4. 4. Imaging Procedures in the SEM. - References. - 14. Low-Temperature Specimen Preparation. - 14. 1. Introduction. - 14. 2. The Properties of Liquid Water and Ice. - 14. 3. Conversion of Liquid Water to Ice. - 14. 4. Specimen Pretreatment before Rapid (Quench) Cooling. - 14. 4. 1. Minimizing Sample Size and Specimen Holders. - 14. 4. 2. Maximizing Undercooling. - 14. 4. 3. Altering the Nucleation Process. - 14. 4. 4. Artificially Depressing the Sample Freezing Point. - 14. 4. 5. Chemical Fixation. - 14. 5. Quench Cooling. - 14. 5. 1. Liquid Cryogens. - 14. 5. 2. Solid Cryogens. - 14. 5. 3. Methods for Quench Cooling. - 14. 5. 4. Comparison of Quench Cooling Rates. - 14. 6. Low-Temperature Storage and Sample Transfer. - 14. 7. Manipulation of Frozen Specimens: Cryosectioning, Cryofracturing, and Cryoplaning. - 14. 7. 1. Cryosectioning. - 14. 7. 2. Cryofracturing. - 14. 7. 3. Cryopolishing or Cryoplaning. - 14. 8. Ways to Handle Frozen Liquids within the Specimen. - 14. 8. 1. Frozen-Hydrated and Frozen Samples. - 14. 8. 2. Freeze-Drying. - 14. 8. 2. 1. Physical Principles Involved in Freeze-Drying. - 14. 8. 2. 2. Equipment Needed for Freeze-Drying. - 14. 8. 2. 3. Artifacts Associated with Freeze-Drying. - 14. 8. 3. Freeze Substitution and Low-Temperature Embedding. - 14. 8. 3. 1. Physical Principles Involved in Freeze Substitution and Low-Temperature Embedding. - 14. 8. 3. 2. Equipment Needed for Freeze Substitution and Low-Temperature Embedding. - 14. 9. Procedures for Hydrated Organic Systems. - 14. 10. Procedures for Hydrated Inorganic Systems. - 14. 11. Procedures for Nonaqueous Liquids. - 14. 12. Imaging and Analyzing Samples at Low Temperatures. - References. - 15. Procedures for Elimination of Charging in Nonconducting Specimens. - 15. 1. Introduction. - 15. 2. Recognizing Charging Phenomena. - 15. 3. Procedures for Overcoming the Problems of Charging. - 15. 4. Vacuum Evaporation Coating. - 15. 4. 1. High-Vacuum Evaporation Methods. - 15. 4. 2. Low-Vacuum Evaporation Methods. - 15. 5. Sputter Coating. - 15. 5. 1. Plasma Magnetron Sputter Coating. - 15. 5. 2. Ion Beam and Penning Sputtering. - 15. 6. High-Resolution Coating Methods. - 15. 7. Coating for Analytical Studies. - 15. 8. Coating Procedures for Samples Maintained at Low Temperatures. - 15. 9. Coating Thickness. - 5. 10. Damage and Artifacts on Coated Samples. - 15. 11. Summary of Coating Guidelines. - References. - Enhancements CD.